Electronics and Electrical Engineering interview Question and Answers for fresh engineers (Part 7)
In this topic we know about the Power Factor, the leading and lagging condition for the power factor, the disadvantage of the low Power Factor and the main causes of the low power factor.
Question: What is Power Factor?
Answer: In an a.c. circuit
the cosine of angle between voltage and current is called as power factor.
Fig: Power factor angles |
Question: What are the leading and lagging conditions in the power factor improvement?
Answer: Normally there are
two types of circuit, capacitive and inductive circuits.
·
In the capacitive
circuits, current leads the voltage and power factor is called as leading.
·
In the inductive
circuits, current lags behinds the voltage and power factor is called as
lagging.
Question: What are the disadvantages of low power factor?
Answer: The main
disadvantages of low power factor are as follows,
1.
Large size of the
Conductor.
2.
Large Kilo Volt
Ampere rating of the electrical machinery or equipment.
3.
Poor or
unaccepted voltage regulations.
4.
A big amount of
Copper loss.
5.
The handling
capacity of the system reduced.
Question: What are the main causes of the low power factor?
Answer: In the supply system
normally the power factor is lower then 0.8 for the overall load. Low Power
factor is very undesirable, because it hampers the economic parameters for the
power generation and distribution. Now, some short important causes are as
follows,
·
In the low
lagging factor some electrical equipment such as electric discharge lamps, Arc
lamps and the industrial heating furnaces are running.
·
The power factor
is also depending on the load conditions. The load is varying time to time. The supply voltage is increasing in the low
load period which increases the amount of the magnetization current. This
magnetizing current is resulting in the decreased power factor.
·
The single phase
and three phase ac motors have low lagging power factor and they are induction
type also. The power factor is varying for these types of motor. It can run
from 0.2 to 0.9 values depends on load. In the heavy load the power factor can
be 0.8 or 0.9 and in the light load the power factor can be 0.2 to 0.3.
-- - - - -- --- -
-- - - -- - - - -- - -- - - - - - -- - - - -- - - - - - - - -
We will give more
important questions and answers for electrical engineering interview very soon.
Please subscribed to RSS feed or Email feed. We need your help for the
betterment of the site. Please give comments and tell us what’s your opinions
and needs from us. We will try to give your required things.
4 comments:
That is really a great blog which is sharing great questions and answers regarding the project means electrical.
Electrical Power Transformers
Thanks
This is awesome. The answers are precise and helps to recall some of the stuff learnt during study
I am really grateful to have the information from this blog.Gold Coast Electrical Services
Post a Comment